33300 Egypt Lane , Suite J100 The Woodlands, TX, 77354
Coating Thickness Gauges and Instruments 877 285 4704 Call Toll Free
Skype Logo
ups logo

Turbidity Meter

CAT. LT-TU2016
Call Us For A Quote Today 281 789 7215


Privacy Policy

Description:

Four operation buttons and two calibration points, easy operation.Jumbo LCD, easy readout. Microprocessor circuit assures maximum possible accuracy, provides special functions and features. Battery operated for field and on-site testing convenience. Data hold and Min/Max functions Heavy duty & compact housing with hard carrying case.

Turbidity Meter Tests Municipal Water, Food, and Beverages


Features
  • Designed to meet ISO 7027.
  • NTU ( Nephelometric TURBIDITY Unit ) measuring unit.
  • Wide and auto measurement range : 0 to 1,000 NTU.
  • High resolution : 0.01 NTU/1 NTU.
  • The unique optics structure, enables the instrument to read low value of TURBIDITY to the high level up to 1,000 NTU.
  • Four operation buttons and three calibration points, easy operation.
  • Jumbo LCD, easy readout.
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
  • Three point push button calibration, easy operation.
  • Battery operated for field and on-site testing convenience.
  • Data hold function for freezing the desired value on display.
  • Records Maximum and Minimum readings with Recall.
  • Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation.
  • Auto shut off is available to save battery life.
  • Application : Test municipal water, food and beverage
General Specifications
Circuit Custom one-chip of microprocessor LSI circuit.
Display LCD size : 41 mm x 34 mm
Range 0.00 to 50.00 NTU, 50 to 1,000 NTU
* NTU : Nephelonietrk Turbidity Unit
* Auto tame
Resolution 0.01 NTU/ 1 NTU
Accuracy ± 5 % F.S. or ± 0.5 NMI, which ever is greater.
Light source LED, 850 nm.
Detector Photo diode
Standard Meet ISO 7027.
Response time Less than 10 seconds.
Sample volume needed 10 mL.
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Display Sampling Time Approx. 1 second.
Power off Auto shut off saves battery life or manual off by
push button.
Calibration points 0 NTU, 10 NTU, 500 NTU.
Operating Temperature 0 to 50 C.
Operating Humidity Less than 85% R.H.
Power Supply DC 1.5 V battery ( Um4, AM ) x 6 PCs, or equivalent.
Power Current Stand by: Approx. DC: 3.5 mA.
Testing: Approx. DC 36 rnA.
Weight 320 g/0.70 LB. g Battery is included
Dimension 155 x 76 x 62 mm ( 6.1 x 3.0 x 2.4 inch)
Accessories Included 0 NTU standard solution (TU-ONTU) 1 bottle
10 NTU standard solution (TU-10NTU )  1 bottle
Testing bottle with 0 NTU standard solution 1 PC
Testing bottle with 10 NTU standard solution 1 PC
Empty testing bottle  2 PCs
Clean cloth 1 PC
Clean solution ( Distill water )  1 bottle
Hard carrying case, CA-08  1 PC
Optional Accessories 500 NTU standard solution
Contact

For further information about this instrument please fill in the contact form below and a salesperson will contact you.

Company NAme Mail Phone Address
Message

Tell a friend

Let a friend or colleague know about this instrument


Your Name Your Mail friend name friend Mail

Message
MAIN OFFICE:
Black Knight Instrument Company LLC
33300 Egypt Lane
Suite J100
The Woodlands TX 77354

SHIPPING ADDRESS:
Black Knight Instrument Company LLC
945 McKinney
# 648
Houston TX 77002


E-Mail: sales@bkinstruments.com
Call Toll Free: 877 285 4704
Phone: (281) 789 7215 - Fax: (281) 864 4854
Privacy Policy • Sitemap
All Rights Reserved, 2011 Black Knight