Digital Anemometer - Cup Anemometer, Barometer, Humidity, and Temperature.

| Display | LCD size : 28 mm x 19 mm. |
|---|---|
| Anemometer Unit | m/S (meters per second) Km/h ( kilometers per hour ) FPM ( feet per minute ) mph ( miles per hour ) Knot ( nautical miles per hour ) |
| Temp. unit | °C, °F |
| Barometer unit | hPa, mmHg, inHg. |
| Humidity unit | %RH |
| Dew point | °C, °F |
| Circuit | Custom one-chip of microprocessor LSI circuit. |
| Sensor Structure | Anemometer: Cup van probe with lowfriction ball bearing design. Barometer: Semiconductor Humidity: Capacitance humidity sensor, semiconductor Temperature: Semiconductor |
| Data Hold | Freeze the display reading. |
| Memory Recall | Maximum & Minimum value. |
| Sampling Time | Approx. 1 second. |
| Power off | Auto shut off saves battery life or manual off( REC function ). |
| Operating Temperature | 0 to 50°C |
| Operating Humidity | Less than 80% R.H. |
| Power Supply | DC 1.5 V battery ( UM4/AAA ) x 4 PCs, |
| Power Current | Approx. DC 5.2 mA |
| Weight | 182 g/ 0.4 LB.@ Battery is included. |
| Dimension | Main instrument: 190 x 40 x 32 mm (7.5" x 1.6" x 1.3") Cup vane ( 3 cups with arm ): 135 mm dia. |
| Accessories Included | Instruction manual...................... 1 PC Hard carrying case...................... 1 PC |
| Anemometer (Air Velocity) | |||
|---|---|---|---|
| Measurement | Range | Resolution | Accuracy |
| m/S | 0.9 - 35.0 m/S | 0.1 m/S | ±(2% + 0.2 m/S) |
| Km/h | 2.5 - 126.0 Km/h | 0.1 Km/h | ±(2% + 0.8 Km/h) |
| FPM | 144 - 6895 Ft/min | 1 Ft/min | ±(2% + 40 Ft/min) |
| mph | 1.6 - 78.2 Mile/h | 0.1 Mile/h | ±(2% + 0.4 Mile/h) |
| Knot | 1.4 - 68.0 Knots | 0.1 Knots | ±(2% + 0.4 Knots) |
| Note : m/S (meters per second),mph ( miles per hour ), Km/h ( kilometers per hour ), Knot ( nautical miles per hour ), FPM ( feet per minute ) | |||
| Temperature | ||
|---|---|---|
| Measuring Range | 0 to 50°C | 32 to 122°F |
| Resolution | 0.1°C | 0.1°F |
| Accuracy | ±0.8°C | ±1.5°F |
| Humidity / Dew point | ||
|---|---|---|
| a. Humidity | ||
| Range | 10 % to 95 % R.H. | |
| Resolution | 0.1 % R.H. | |
| Accuracy | ≥70% RH:
± (3% reading + 1% RH) <70% RH - 3% RH: ±3% RH |
|
| b. Dew point | ||
| °C | Range | -25.3 to 48.9°C |
| Resolution | 0.01°C | |
| °F | Renge | -13.5 to 120.1°F |
| Resolution | 0.01°F | |
| Remark : • Dew Point display value is calculated from the Humidity/Temp. measurement automatically •The Dew Point accuracy is sum accuracy value of Humidity & Temperature measurement. |
||
| Barometer | |||
|---|---|---|---|
| Measurement | Range | Resolution | Accuracy@Reading |
| hPa | 10.0 to 999.9 | 0.1 | ± 1.5 hPa |
| 1000 to 1100 | 1 | ± 2 hPa | |
| mmHg | 7.5 to 825.0 | 0.1 | ± 1.2mmHg |
| inHg. | 0.29 to 32.48 | 0.01 | ± 0.05inHg |
| MAIN OFFICE: Black Knight Instrument Company LLC 33300 Egypt Lane Suite J100 The Woodlands TX 77354 |
SHIPPING ADDRESS: |